Skip to content Skip to footer
GenePath Dx Cytomegalovirus (CMV) qPCR Kit​
RuO
  • DESCRIPTION: Highly specific multiplexed assay with four target genes for the detection and quantification of CMV.
  • SAMPLE TYPE: EDTA peripheral blood
  • REACTION VOLUME: 15 μL
  • LIMIT OF DETECTION: 0.5 copies/μL
  • WORKFLOW: Uses the ‘UNG/dUTP’ system to minimize the risk of PCR carry-over contamination and includes an internal process control (IC)
  • INSTRUMENT COMPATIBILITY: Qiagen Rotor-Gene Q, Bio-Rad CFX96, Bio-Rad Opus, Roche LightCycler II 480 and Thermo/ABI QuantStudio5 and 7500 FAST
  • RUN TIME: ~ 90 mins
  • SOFTWARE: Secure online tool to assist with data analysis and calculate viral load
GenePath Dx Epstein-Barr virus (EBV) qPCR Kit​
RuO
  • DESCRIPTION: Highly specific multiplexed assay with two target genes for the detection and quantification of EBV
  • SAMPLE TYPE: EDTA peripheral blood or plasma
  • REACTION VOLUME: 25 μL
  • LIMIT OF DETECTION: 0.5 copies/μL
  • WORKFLOW: Uses the ‘UNG/dUTP’ system to minimize the risk of PCR carry-over contamination and includes the human RNAseP gene as an endogenous process control
  • INSTRUMENT COMPATIBILITY: Qiagen Rotor-Gene Q, Bio-Rad CFX96, Bio-Rad Opus, Roche LightCycler II 480 and Thermo/ABI QuantStudio5 and 7500 FAST
  • RUN TIME: ~ 70 mins
  • SOFTWARE: Secure online tool to assist with data analysis and calculate viral load

US Office

674 South Wagner Road Ann Arbor Michigan 48103 USA

US Laboratory

600 South Wagner Road Ann Arbor Michigan 48103 USA

Registered India Office

1260/B Jangli Maharaj Road, Plot 596 Above Phadke Hospital, across from McDonald’s Deccan Gymkhana, Shivajinagar, Pune, Maharashtra 411004 India 

Pune Laboratory

7th Floor, Manikchand Galleria CTS No. 996, Plot No. 383 Swastik Society, Model Colony Pune, Maharashtra 411016 India 

Pune Manufacturing Facility

Gut No. 64/1, Sawardari Opposite Philips Company, Chakan, Pune, Maharashtra 410501, India.
 

GenePath Diagnostics © 2024. All Rights Reserved.

US Office

674 South Wagner Road Ann Arbor Michigan 48103 USA

US Laboratory

600 South Wagner Road Ann Arbor Michigan 48103 USA

Registered India Office

1260/B Jangli Maharaj Road, Plot 596 Above Phadke Hospital, across from McDonald’s Deccan Gymkhana, Shivajinagar, Pune, Maharashtra 411004 India 

Pune Laboratory

7th Floor, Manikchand Galleria CTS No. 996, Plot No. 383 Swastik Society, Model Colony Pune, Maharashtra 411016 India 

Pune Manufacturing Facility

Gut No. 64/1, Sawardari Opposite Philips Company, Chakan, Pune, Maharashtra 410501, India.
 

GenePath Diagnostics © 2024. All Rights Reserved.