Skip to content Skip to footer
GenePath Dx CoViQuick v2.0 – Extraction-less
CE Approved
  • DESCRIPTION: Combined kit for rapid sample preparation and RT-qPCR testing of SARS-CoV-2
  • SAMPLE TYPE: Nasopharyngeal, oropharyngeal, nasopharyngeal + oropharyngeal, or nasal swab specimens.
  • REACTION VOLUME: 15 μL
  • LIMIT OF DETECTION: 0.5 copies/μL
  • WORKFLOW: Includes the proprietary ‘CoviPrep’ rapid (3 minutes) single-step sample preparation reagent. Uses the ‘UNG/dUTP’ system to minimize the risk of PCR carry-over contamination and includes the human RNAse P gene as an endogenous process control.
  • INSTRUMENT COMPATIBILITY: Qiagen Rotor-Gene Q, Bio-Rad CFX96, Bio-Rad Opus, Roche LightCycler II 480 and Thermo/ABI QuantStudio5 and 7500 FAST
  • RUN TIME: 75 mins 
GenePath Dx CoViFast v2.0 RT-qPCR Kit – Extraction-less
CE Approved
  • DESCRIPTION: Single tube rapid cycle time RT-qPCR test kit for four independent SARS-CoV-2 specific targets multiplexed into two channels
  • SAMPLE TYPE: Nasopharyngeal, oropharyngeal, nasopharyngeal + oropharyngeal, or nasal swab specimens.
  • REACTION VOLUME: 15 μL
  • LIMIT OF DETECTION: 2 copies/μL
  • WORKFLOW: Includes the proprietary ‘CoviPrep’ rapid (3 minutes) single-step sample preparation reagent. Includes the human RNAse P gene as an endogenous process control.
  • INSTRUMENT COMPATIBILITY: Bio-Rad CFX 96 Touch (35 minutes), Bio-Rad CFX Opus (44 minutes), Applied Biosystems QuantStudio 5 (39 minutes) and Qiagen Rotor-Gene Q (57 minutes)
  • RUN TIME: 35 minutes on Bio-Rad CFX96 Touch (run time may vary from machine to machine)
Waste Water Surveillance for Covid Management
RuO
  • DESCRIPTION: Single tube multiplexed RT-qPCR kit using four independent targets on the Covid-19 genome. Standards provided with the kit can be used for the quantification of SARS-CoV-2. viral load 
  • SAMPLE TYPE: Nasopharyngeal, oropharyngeal, nasopharyngeal + oropharyngeal, or nasal swab specimens. 
  • REACTION VOLUME: 15 μL 
  • LIMIT OF DETECTION: 0.5 copies/μL 
  • WORKFLOW: Uses the ‘UNG/dUTP’ system to minimize the risk of PCR carry-over contamination and includes the human RNAse P gene as an endogenous process control. 
  • INSTRUMENT COMPATIBILITY: Qiagen Rotor-Gene Q, Bio-Rad CFX96, Bio-Rad Opus, Roche LightCycler II 480 and Thermo/ABI QuantStudio5 and 7500 FAST 
  • RUN TIME: 75 mins 
  • SOFTWARE: Secure online tool to assist with viral load calculation and data analysis

US Office

674 South Wagner Road Ann Arbor Michigan 48103 USA

US Laboratory

600 South Wagner Road Ann Arbor Michigan 48103 USA

Registered India Office

1260/B Jangli Maharaj Road, Plot 596 Above Phadke Hospital, across from McDonald’s Deccan Gymkhana, Shivajinagar, Pune, Maharashtra 411004 India 

Pune Laboratory

7th Floor, Manikchand Galleria CTS No. 996, Plot No. 383 Swastik Society, Model Colony Pune, Maharashtra 411016 India 

Pune Manufacturing Facility

Gut No. 64/1, Sawardari Opposite Philips Company, Chakan, Pune, Maharashtra 410501, India.
 

GenePath Diagnostics © 2024. All Rights Reserved.

US Office

674 South Wagner Road Ann Arbor Michigan 48103 USA

US Laboratory

600 South Wagner Road Ann Arbor Michigan 48103 USA

Registered India Office

1260/B Jangli Maharaj Road, Plot 596 Above Phadke Hospital, across from McDonald’s Deccan Gymkhana, Shivajinagar, Pune, Maharashtra 411004 India 

Pune Laboratory

7th Floor, Manikchand Galleria CTS No. 996, Plot No. 383 Swastik Society, Model Colony Pune, Maharashtra 411016 India 

Pune Manufacturing Facility

Gut No. 64/1, Sawardari Opposite Philips Company, Chakan, Pune, Maharashtra 410501, India.
 

GenePath Diagnostics © 2024. All Rights Reserved.